Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
BMJ Mil Health ; 2023 Feb 09.
Article in English | MEDLINE | ID: covidwho-2228278

ABSTRACT

BACKGROUND: SARS-CoV-2 can spread rapidly on maritime platforms. Several outbreaks of SARS-CoV-2 have been reported on warships at sea, where transmission is facilitated by living and working in close quarters. Core components of infection control measures such as social distancing, patient isolation and quarantine of exposed persons are extremely difficult to implement. Whole genome sequencing (WGS) of SARS-CoV-2 has facilitated epidemiological investigations of outbreaks, impacting on outbreak management in real time by identifying transmission patterns, clusters of infection and guiding control measures. We suggest such a capability could mitigate against the impact of SARS-CoV-2 in maritime settings. METHODS: We set out to establish SARS-CoV-2 WGS using miniaturised nanopore sequencing technology aboard the Royal Fleet Auxiliary ARGUS while at sea. Objectives included designing a simplified protocol requiring minimal reagents and processing steps, the use of miniaturised equipment compatible for use in limited space, and a streamlined and standalone data analysis capability to allow rapid in situ data acquisition and interpretation. RESULTS: Eleven clinical samples with blinded SARS-CoV-2 status were tested at sea. Following viral RNA extraction and ARTIC sequencing library preparation, reverse transcription and ARTIC PCR-tiling were performed. Samples were subsequently barcoded and sequenced using the Oxford Nanopore MinION Mk1B. An offline version of the MinKNOW software was used followed by CLC Genomics Workbench for downstream analysis for variant identification and phylogenetic tree construction. All samples were correctly classified, and relatedness identified. CONCLUSIONS: It is feasible to establish a small footprint sequencing capability to conduct SARS-CoV-2 WGS in a military maritime environment at sea with limited access to reach-back support. This proof-of-concept study has highlighted the potential of deploying such technology in the future to military environments, both maritime and land-based, to provide meaningful clinical data to aid outbreak investigations.

2.
J Mol Diagn ; 24(4): 320-336, 2022 04.
Article in English | MEDLINE | ID: covidwho-1895234

ABSTRACT

Previous studies have described reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for the rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal/oropharyngeal swab and saliva samples. This multisite clinical evaluation describes the validation of an improved sample preparation method for extraction-free RT-LAMP and reports clinical performance of four RT-LAMP assay formats for SARS-CoV-2 detection. Direct RT-LAMP was performed on 559 swabs and 86,760 saliva samples and RNA RT-LAMP on extracted RNA from 12,619 swabs and 12,521 saliva samples from asymptomatic and symptomatic individuals across health care and community settings. For direct RT-LAMP, overall diagnostic sensitivity (DSe) was 70.35% (95% CI, 63.48%-76.60%) on swabs and 84.62% (95% CI, 79.50%-88.88%) on saliva, with diagnostic specificity of 100% (95% CI, 98.98%-100.00%) on swabs and 100% (95% CI, 99.72%-100.00%) on saliva, compared with quantitative RT-PCR (RT-qPCR); analyzing samples with RT-qPCR ORF1ab CT values of ≤25 and ≤33, DSe values were 100% (95% CI, 96.34%-100%) and 77.78% (95% CI, 70.99%-83.62%) for swabs, and 99.01% (95% CI, 94.61%-99.97%) and 87.61% (95% CI, 82.69%-91.54%) for saliva, respectively. For RNA RT-LAMP, overall DSe and diagnostic specificity were 96.06% (95% CI, 92.88%-98.12%) and 99.99% (95% CI, 99.95%-100%) for swabs, and 80.65% (95% CI, 73.54%-86.54%) and 99.99% (95% CI, 99.95%-100%) for saliva, respectively. These findings demonstrate that RT-LAMP is applicable to a variety of use cases, including frequent, interval-based direct RT-LAMP of saliva from asymptomatic individuals who may otherwise be missed using symptomatic testing alone.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , RNA, Viral/analysis , RNA, Viral/genetics , SARS-CoV-2/genetics , Saliva , Sensitivity and Specificity
3.
Proc Natl Acad Sci U S A ; 118(35)2021 08 31.
Article in English | MEDLINE | ID: covidwho-1360222

ABSTRACT

A rapid isothermal method for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the virus responsible for COVID-19, is reported. The procedure uses an unprecedented reverse transcription-free (RTF) approach for converting genomic RNA into DNA. This involves the formation of an RNA/DNA heteroduplex whose selective cleavage generates a short DNA trigger strand, which is then rapidly amplified using the exponential amplification reaction (EXPAR). Deploying the RNA-to-DNA conversion and amplification stages of the RTF-EXPAR assay in a single step results in the detection, via a fluorescence read-out, of single figure copy numbers per microliter of SARS-CoV-2 RNA in under 10 min. In direct three-way comparison studies, the assay has been found to be faster than both RT-qPCR and reverse transcription loop-mediated isothermal amplification (RT-LAMP), while being just as sensitive. The assay protocol involves the use of standard laboratory equipment and is readily adaptable for the detection of other RNA-based pathogens.


Subject(s)
COVID-19 Testing/methods , COVID-19/virology , Nucleic Acid Amplification Techniques/methods , RNA, Viral/genetics , SARS-CoV-2/genetics , COVID-19/diagnosis , Humans , Reverse Transcription , SARS-CoV-2/isolation & purification , Sensitivity and Specificity
4.
J Infect Dis ; 223(10): 1666-1670, 2021 05 28.
Article in English | MEDLINE | ID: covidwho-1246717

ABSTRACT

A SARS-CoV-2 variant B1.1.7 containing mutation Δ69/70 has spread rapidly in the United Kingdom and shows an identifiable profile in ThermoFisher TaqPath RT-qPCR, S gene target failure (SGTF). We analyzed recent test data for trends and significance. Linked cycle threshold (Ct) values for respiratory samples showed that a low Ct for ORF1ab and N were clearly associated with SGTF. Significantly more SGTF samples had higher inferred viral loads between 1×107 and 1×108. Our conclusion is that patients whose samples exhibit the SGTF profile are more likely to have high viral loads, which may explain higher infectivity and rapidity of spread.


Subject(s)
COVID-19/virology , Polymerase Chain Reaction/methods , SARS-CoV-2/physiology , Viral Load , COVID-19/epidemiology , Humans , Linear Models , Polymerase Chain Reaction/standards , SARS-CoV-2/classification , SARS-CoV-2/genetics , Taq Polymerase
5.
PLoS Biol ; 19(4): e3001216, 2021 04.
Article in English | MEDLINE | ID: covidwho-1207620

ABSTRACT

Lateral flow devices (LFDs) are quickly being implemented for use in large-scale population surveillance programs for SARS-CoV-2 infection in the United Kingdom. These programs have been piloted in city-wide screening in the city of Liverpool and are now being rolled out to support care home visits and the return home of University students for the Christmas break. Here, we present data on the performance of LFDs to test almost 8,000 students at the University of Birmingham between December 2 and December 9, 2020. The performance is validated against almost 800 samples using PCR performed in the University Pillar 2 testing lab and theoretically validated on thousands of Pillar 2 PCR testing results performed on low-prevalence care home testing samples. Our data show that LFDs do not detect infections presenting with PCR Ct values over 29 to 30 as determined using the Thermo Fisher TaqPath asssay. This may be of particular importance in detecting individuals that are either at the early, or late stages of infection, and reinforces the need for frequent, recurrent testing.


Subject(s)
COVID-19 Serological Testing , COVID-19/diagnosis , Carrier State/diagnosis , SARS-CoV-2/isolation & purification , COVID-19/epidemiology , COVID-19 Nucleic Acid Testing , Carrier State/epidemiology , Humans , Immunoassay , Mass Screening , Prevalence , SARS-CoV-2/genetics , SARS-CoV-2/immunology , Sensitivity and Specificity , United Kingdom/epidemiology , Universities
6.
Clin Microbiol Infect ; 27(9): 1348.e1-1348.e7, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1201402

ABSTRACT

OBJECTIVES: Rapid, high throughput diagnostics are a valuable tool, allowing the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in populations so as to identify and isolate people with asymptomatic and symptomatic infections. Reagent shortages and restricted access to high throughput testing solutions have limited the effectiveness of conventional assays such as quantitative RT-PCR (RT-qPCR), particularly throughout the first months of the coronavirus disease 2019 pandemic. We investigated the use of LamPORE, where loop-mediated isothermal amplification (LAMP) is coupled to nanopore sequencing technology, for the detection of SARS-CoV-2 in symptomatic and asymptomatic populations. METHODS: In an asymptomatic prospective cohort, for 3 weeks in September 2020, health-care workers across four sites (Birmingham, Southampton, Basingstoke and Manchester) self-swabbed with nasopharyngeal swabs weekly and supplied a saliva specimen daily. These samples were tested for SARS-CoV-2 RNA using the Oxford Nanopore LamPORE system and a reference RT-qPCR assay on extracted sample RNA. A second retrospective cohort of 848 patients with influenza-like illness from March 2020 to June 2020 were similarly tested from nasopharyngeal swabs. RESULTS: In the asymptomatic cohort a total of 1200 participants supplied 23 427 samples (3966 swab, 19 461 saliva) over a 3-week period. The incidence of SARS-CoV-2 detection using LamPORE was 0.95%. Diagnostic sensitivity and specificity of LamPORE was >99.5% (decreasing to approximately 98% when clustered estimation was used) in both swab and saliva asymptomatic samples when compared with the reference RT-qPCR test. In the retrospective symptomatic cohort, the incidence was 13.4% and the sensitivity and specificity were 100%. CONCLUSIONS: LamPORE is a highly accurate methodology for the detection of SARS-CoV-2 in both symptomatic and asymptomatic population settings and can be used as an alternative to RT-qPCR.


Subject(s)
COVID-19/diagnosis , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , Pandemics , SARS-CoV-2/isolation & purification , COVID-19/virology , Cohort Studies , Coronavirus Nucleocapsid Proteins/genetics , Humans , Limit of Detection , Nanopore Sequencing , Nasopharynx/virology , Polyproteins/genetics , Prospective Studies , Reproducibility of Results , Retrospective Studies , SARS-CoV-2/genetics , Saliva/virology , Sensitivity and Specificity , Viral Proteins/genetics
8.
Thorax ; 75(12): 1089-1094, 2020 12.
Article in English | MEDLINE | ID: covidwho-760280

ABSTRACT

OBJECTIVE: To determine the rates of asymptomatic viral carriage and seroprevalence of SARS-CoV-2 antibodies in healthcare workers. DESIGN: A cross-sectional study of asymptomatic healthcare workers undertaken on 24/25 April 2020. SETTING: University Hospitals Birmingham NHS Foundation Trust (UHBFT), UK. PARTICIPANTS: 545 asymptomatic healthcare workers were recruited while at work. Participants were invited to participate via the UHBFT social media. Exclusion criteria included current symptoms consistent with COVID-19. No potential participants were excluded. INTERVENTION: Participants volunteered a nasopharyngeal swab and a venous blood sample that were tested for SARS-CoV-2 RNA and anti-SARS-CoV-2 spike glycoprotein antibodies, respectively. Results were interpreted in the context of prior illnesses and the hospital departments in which participants worked. MAIN OUTCOME MEASURE: Proportion of participants demonstrating infection and positive SARS-CoV-2 serology. RESULTS: The point prevalence of SARS-CoV-2 viral carriage was 2.4% (n=13/545). The overall seroprevalence of SARS-CoV-2 antibodies was 24.4% (n=126/516). Participants who reported prior symptomatic illness had higher seroprevalence (37.5% vs 17.1%, χ2=21.1034, p<0.0001) and quantitatively greater antibody responses than those who had remained asymptomatic. Seroprevalence was greatest among those working in housekeeping (34.5%), acute medicine (33.3%) and general internal medicine (30.3%), with lower rates observed in participants working in intensive care (14.8%). BAME (Black, Asian and minority ethnic) ethnicity was associated with a significantly increased risk of seropositivity (OR: 1.92, 95% CI 1.14 to 3.23, p=0.01). Working on the intensive care unit was associated with a significantly lower risk of seropositivity compared with working in other areas of the hospital (OR: 0.28, 95% CI 0.09 to 0.78, p=0.02). CONCLUSIONS AND RELEVANCE: We identify differences in the occupational risk of exposure to SARS-CoV-2 between hospital departments and confirm asymptomatic seroconversion occurs in healthcare workers. Further investigation of these observations is required to inform future infection control and occupational health practices.


Subject(s)
Antibodies, Viral/blood , Asymptomatic Diseases , COVID-19/diagnosis , Health Personnel/statistics & numerical data , Pandemics , SARS-CoV-2/immunology , Adult , COVID-19/epidemiology , COVID-19/virology , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , RNA, Viral/analysis , SARS-CoV-2/genetics , Seroepidemiologic Studies
9.
J Clin Virol ; 128: 104469, 2020 07.
Article in English | MEDLINE | ID: covidwho-343387

ABSTRACT

BACKGROUND: In January 2020 reports of unidentified severe respiratory illness were described in Wuhan, China. A rapid expansion in cases affecting most countries around the globe led to major changes in the way people live their daily lives. In the United Kingdom, the Department of Health and Social Care directed healthcare providers to establish additional resources to manage the anticipated surge in cases that could overwhelm the health services. A priority area was testing for SARS-CoV-2 RNA and its detection by qualitative RT-PCR. DESIGN: A laboratory workflow twinning research environment with clinical laboratory capabilities was implemented and validated in the University of Birmingham within 4 days of the project initiation. The diagnostic capability was centred on an IVD CE-marked RT-PCR kit and designed to provide surge capacity to the nearby Queen Elizabeth Hospital. The service was initially tasked with testing healthcare workers (HCW) using throat swabs, and subsequently the process investigated the utility of using saliva as an alternative sample type. RESULTS: Between the 8th April 2020 and the 30th April 2020, the laboratory tested a total of 1282 HCW for SARS-CoV-2 RNA in throat swabs. RNA was detected in 54 % of those who reported symptoms compatible with COVID-19, but in only 4% who were asymptomatic. CONCLUSION: This capability was established rapidly and utilised a cold-chain free methodology, applicable to a wide range of settings, and which can provide surge capacity and support to clinical laboratories facing increasing pressure during periods of national crisis.


Subject(s)
Betacoronavirus/isolation & purification , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , RNA, Viral/blood , Betacoronavirus/genetics , COVID-19 , COVID-19 Testing , Coronavirus Infections/virology , Humans , Pandemics , Pneumonia, Viral/virology , SARS-CoV-2 , Saliva/virology , Surge Capacity , United Kingdom , Workflow
SELECTION OF CITATIONS
SEARCH DETAIL